Use Emonhub with RPICT
Overview
/!\ DO NOT USE THIS GUIDE WITH EMONPI / EMONCMS IMAGE. /!\
This is for use on a native Raspbian image. If using the emoncms image this is not necessary as emonhub is already installed.
This document will demonstrate how to prepare the rasberrypi to use Emonhub with the RPICT.
Emonhub will be used to forward the data from the RPICT series board and forward them to Emoncms.
We assume here a fresh install of raspbian has been installed and all steps to get the serial port operating have been carried out. See Howto_setup_Raspbian_for_serial_read.
Also make sure the RPICT board supports Emonhub format as output.
Install Emonhub
This is not necessary if you are using the image from Emoncms as emonhub is already installed.
To install emonhub we would recommend following the steps indicated on the emonhub github page.
We have summarized the commands to executre below:
wget http://repo.mosquitto.org/debian/mosquitto-repo.gpg.key sudo apt-key add mosquitto-repo.gpg.key cd /etc/apt/sources.list.d/ sudo wget http://repo.mosquitto.org/debian/mosquitto-jessie.list sudo apt-get update sudo apt-get install -y mosquitto python-serial python-configobj sudo easy_install -U pip sudo pip install paho-mqtt sudo pip install pydispatcher
Open and modify this file below:
sudo nano /etc/mosquitto/mosquitto.conf
Set persistence parameter as false
persistence false
cd mkdir data git clone https://github.com/openenergymonitor/emonhub.git && emonhub/install sudo service emonhub start
RPICT configuration
The format parameter should be set to emonhub, code number 3.
format = 3
Emonhub configuration
The configuration file for emonhub is located in /home/pi/data
Open this file. Delete all its content and replace with this one below:
[hub] ### loglevel must be one of DEBUG, INFO, WARNING, ERROR, and CRITICAL ### see here : http://docs.python.org/2/library/logging.html loglevel = DEBUG #(default:WARNING) [interfacers] [[SerialDirect]] Type = EmonHubSerialInterfacer [[[init_settings]]] com_port = /dev/ttyAMA0 com_baud = 38400 [[[runtimesettings]]] pubchannels = ToEmonCMS, [[emoncmsorg]] Type = EmonHubEmoncmsHTTPInterfacer [[[init_settings]]] [[[runtimesettings]]] subchannels = ToEmonCMS, #url = http://localhost/emoncms #uncomment to save on local pi apikey = xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx senddata = 1 # Enable sending data to Emoncms.org sendstatus = 1 # Enable sending WAN IP to Emoncms.org MyIP > https://emoncms.org/myip/list sendinterval= 30 # Bulk send interval to Emoncms.org in seconds [nodes] [[11]] nodename = my_RPICT7V1 [[[rx]]] names = RP1, RP2, RP3, RP4, RP5, RP6, RP7, Irms1, Irms2, Irms3, Irms4,Irms5,Irms6,Irms7,Vrms scales = 1,1,1,1,1,1,1,1,1,1,1,1,1,1,1 units =W,W,W,W,W,W,W,mA,mA,mA,mA,mA,mA,mA,V
Change the node information as relevant. Also change the apikey to the one that emoncms gave you.