Noise level test RPICT V2&3: Difference between revisions

From lechacal
Jump to navigation Jump to search
(Created page with " Evaluation of background noise level for RPICT series version 2 & 3. {| class="wikitable" |+ |- !Sensor !Range<br> (Rms Amps) !Burden Resistor<br> (Ohm) !Calibration Coeff...")
 
No edit summary
Line 9: Line 9:
!Range<br> (Rms Amps)
!Range<br> (Rms Amps)
!Burden Resistor<br> (Ohm)
!Burden Resistor<br> (Ohm)
!Calibration Coefficient<br> (theoretical)
!Calibration Coefficient
!Mean Noise (mA)
!Estimated Power (W)(110V)
!Estimated Power (W)(220V)
!Estimated Power (W)(240V)
|-
|-
| '''SCT-019-000'''
| '''SCT-019-000'''
Line 15: Line 19:
| 33
| 33
| 181.82
| 181.82
|466.8
|51.3
|102.7
|112.0
|-
|-
| rowspan=6 | '''SCT-013-000'''
| rowspan=6 | '''SCT-013-000'''
Line 20: Line 28:
| 24
| 24
| 83.33
| 83.33
|202.0
|22.2
|44.4
|48.5
|-
|-
| 60
| 60

Revision as of 14:50, 7 April 2019


Evaluation of background noise level for RPICT series version 2 & 3.

Sensor Range
(Rms Amps)
Burden Resistor
(Ohm)
Calibration Coefficient Mean Noise (mA) Estimated Power (W)(110V) Estimated Power (W)(220V) Estimated Power (W)(240V)
SCT-019-000 200 33 181.82 466.8 51.3 102.7 112.0
SCT-013-000 100 24 83.33 202.0 22.2 44.4 48.5
60 39 51.28
50 47 42.55
30 75 26.67
25 91 21.98
20 120 16.67
SCT-006-000 20 47 17.02