Noise level test RPICT V2&3: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 2: | Line 2: | ||
Evaluation of background noise level for RPICT series version 2 & 3. | Evaluation of background noise level for RPICT series version 2 & 3. | ||
=CT only - RMS Current= | |||
{| class="wikitable" | {| class="wikitable" | ||
Line 11: | Line 13: | ||
!Calibration Coefficient | !Calibration Coefficient | ||
!Mean Noise (mA) | !Mean Noise (mA) | ||
! | !Equiv. Power (W)(110V) | ||
! | !Equiv. Power (W)(220V) | ||
! | !Equiv. Power (W)(240V) | ||
|- | |- | ||
| '''SCT-019-000''' | | '''SCT-019-000''' |
Revision as of 14:57, 7 April 2019
Evaluation of background noise level for RPICT series version 2 & 3.
CT only - RMS Current
Sensor | Range (Rms Amps) |
Burden Resistor (Ohm) |
Calibration Coefficient | Mean Noise (mA) | Equiv. Power (W)(110V) | Equiv. Power (W)(220V) | Equiv. Power (W)(240V) |
---|---|---|---|---|---|---|---|
SCT-019-000 | 200 | 33 | 181.82 | 466.8 | 51.3 | 102.7 | 112.0 |
SCT-013-000 | 100 | 24 | 83.33 | 202.0 | 22.2 | 44.4 | 48.5 |
60 | 39 | 51.28 | 136.5 | 15.0 | 30.0 | 32.8 | |
50 | 47 | 42.55 | 108.3 | 12.0 | 23.8 | 26.0 | |
30 | 75 | 26.67 | 70.9 | 7.8 | 15.6 | 17.0 | |
25 | 91 | 21.98 | 54.8 | 6.0 | 12.1 | 13.2 | |
20 | 120 | 16.67 | 43.0 | 4.7 | 9.46 | 10.3 | |
SCT-006-000 | 20 | 47 | 17.02 | 108.3 | 12.0 | 23.8 | 26.0 |