Evaluation of background noise level for RPICT series version 2 & 3.

CT only - RMS Current

Sensor Range
(Rms Amps)
Burden Resistor
(Ohm)
Calibration Coefficient Mean Noise (mA) Equiv. Power (W)(110V) Equiv. Power (W)(220V) Equiv. Power (W)(240V)
SCT-019-000 200 33 181.82 466.8 51.3 102.7 112.0
SCT-013-000 100 24 83.33 202.0 22.2 44.4 48.5
60 39 51.28 136.5 15.0 30.0 32.8
50 47 42.55 108.3 12.0 23.8 26.0
30 75 26.67 70.9 7.8 15.6 17.0
25 91 21.98 54.8 6.0 12.1 13.2
20 120 16.67 43.0 4.7 9.46 10.3
SCT-006-000 20 47 17.02 108.3 12.0 23.8 26.0