The CT Conditioner allows to connect a Current Transformer to an Arduino Analog pin.

  • Supports both current and voltage output CT.
  • 3.5mm Jack connector CT port.
  • Amplification easily setup by mean of a resistor.
  • Zero offset can be set to Vcc/2 onboard. Or use an external reference.
  • Uses instrument amplifier AD623 for accurate result.
  • Provision of a burden resistor mounting for current output CTs.
  • Minimum setup uses 3 wires. +5V Gnd and analog out.
  • Dimensions: 24x24mm

Link to the shop

Usage

Connect the CT sensor to the jack connector. Then connect 3 wires to the Arduino. The 3 wires to connect are

CT conditioner -> Arduino
  Vcc         -> 5V
  Gnd         -> Gnd
  Out         -> A0

Note Vcc can also be connected to 3.3V.

Compatible CT

Any CT with a 3.5mm jack connector will be supported.

Voltage CT
No burden resistor should be fitted using a Voltage CT. These are commonly
SCT-013-005
SCT-013-010
SCT-013-015
SCT-013-020
SCT-013-025
SCT-013-030
SCT-013-050
SCT-013-060

Current CT
A burden resistor must be used when using current output CT. These are commonly
SCT-013-000
SCT-006
SCT-019

Sketch Example

A simple arduino sketch can be used to read the value every seconds. See the example below.


// CT Conditioner Demo
// Version 1.0
// lechacal.com
//
// Required Libraries
// RPICTlib 1.0.0
// http://lechacal.com/RPICT/RPICTlib/RPICTlib_v1.0.0.zip
//

// Include these 3 lines at the top of the sketch
#include "RPICTlib.h"         // Include the library
uint8_t ADC_BITS = 10;        // Some mandatory global setup 
uint16_t ADC_COUNTS (1 << ADC_BITS);

int sInterval = 400;          // 400usec is 2.5kHz sampling interval (internal sampling)
int NUMBER_OF_SAMPLES = 1000; // We will use 1000 samples to measure the rms signal.

CurrentNode ct1;              // Our CT we will compute with

void setup()
{
  Serial.begin(38400); // Open the serial port

  ct1.init(A0, 30.0); // Analog port A0, 30 scaling factor (using a SCT-013-030)
}

void loop()
{
  ct1.calcIrms(NUMBER_OF_SAMPLES, sInterval); // Measure and compute Irms
  Serial.println(ct1.Irms);                   // Print the result
  delay(1000);                                // wait 1 second
}

Default Setup

By default the CT conditioner comes with no resistors fitted for both Burden and Gain.

This means this is ready for a voltage output CT and the Gain is 1.

Resistor

Fitting

There 2 types of resistor the user can fit on the CT conditioner. These are not mandatory but will help optimising the measurement.

Both surface mount and though hole resistor are supported. Surface mount resistor case are 0805 size.

Burden Resistor

When a current output CT sensor is used a resistor must be soldered to the CT conditioner. It it usually recommended to use a low value resistor. ALso the datasheet of the CT should have some indication on the maximum resistor to use. Burden resistor is also called sampling resistor in some documentations.

Note that you do not need a burden resistor if the CT is voltage output.

Amplification

A second resistor can be fitted on the CT conditioner to adjust the amplification level. Amplification can be required if it is found the levels are too low. For low currents this can increase resolution.

From a desired gain the resistor can be calculated as follow

Rg = 100000/(G -1)

G is the Amplification Gain.
Rg is the resistor value in ohm.

The formulae below should be used to estimate the Gain.

G = Vadc/Vct/2√2

Vadc if the full scale voltage value of the ADC. Usually 5V or 3.3V.
Vct if the output voltage of the current transformer at maximum desired value (rms).

Example

Here is an example of Gain calculation.

Let's take the SCT-013-030. This outputs 1V at 30A (both rms and peak). Hence ICAL = 30.
Using an Arduino UNO the ADC has 5V reference by default. Hence Vadc = 5.
We would like to measure 30A (i.e. 1V) at the maximum scale of the ADC. Hence Vct = 1.

We can estimate the required gain as follow:

G = 5/1/2√2 = 1.77.

Then the required resistor for this Gain is:

Rg = 100000/(1.77-1) = 130Kohm.

We can now calculate the theoretical scaling coefficient to enter in the sketch:

newICAL = ICAL/G = 30/1.77 = 16.95

We will then fit a 130kOhm resistor and enter in the sketch

ct1.init(A0, 16.95);

Recommended Values

CT Output Type Rburden @ 5V Rgain @ 5V ICAL @5V
SCT-013-005 Voltage None 130 kΩ 2.83
SCT-013-010 Voltage None 130 kΩ 5.66
SCT-013-015 Voltage None 130 kΩ 8.49
SCT-013-020 Voltage None 130 kΩ 11.31
SCT-013-025 Voltage None 130 kΩ 14.14
SCT-013-030 Voltage None 130 kΩ 16.97
SCT-013-050 Voltage None 130 kΩ 28.28
SCT-013-060 Voltage None 130 kΩ 33.94
SCT-013-000 Current 10 Ω 40 kΩ 56.57
SCT-019 Current 10 Ω 40 kΩ 56.57
SCT-013-000 Current 10 Ω 24 kΩ 57.14

Vref

Vref is the center of the waveform and is set on the Amplifier.

Why? As most ADC scale are set between 0 and 5V (or other positive voltage) is makes it difficult to measure a waveform with a negative part. We will miss the negative part due to the limit at 0. To face this we can offset the signal higher at say 2.5V. Then when negative the waveform will be below 2.5V and above when positive.

By default Vref is connected to Vcc/2 (2.5V or 1.65V). This is done with the solder blob shown on this picture. The Vcc/2 is achieved using a voltage divider with 2x 10k resistors on the board.

If you prefer using an external Vref then disconnect Vref from Vcc/2 by removing the blob with a soldering iron. Then Vref can be set from an external source on one of the pin of the CT conditioner.