RPI DCV8: Difference between revisions

From lechacal
Jump to navigation Jump to search
No edit summary
Line 2: Line 2:
RPI_DCV8 is a 8 channels acquisition board for Raspberrypi. Any of AC current & voltage or DC current & voltage can be setup at assembly/purchase time.
RPI_DCV8 is a 8 channels acquisition board for Raspberrypi. Any of AC current & voltage or DC current & voltage can be setup at assembly/purchase time.


* 8 Channels (both AC or DC).
* 8 Channels.
* Instrumentation amplifiers.
* Measure RMS or Average signal.
* Measure RMS or Average signal.
* Fit on Raspberrypi 4 holes mounting pattern.
* Fit on Raspberrypi 4 holes mounting pattern.
Line 13: Line 14:


=Channel Setup=
=Channel Setup=
The idea of the RPI_DCV8 brings a customisable base to setup each channel as per your requirement. We will setup for you the channel type and range at purchase time.
Currently supported type of channels are:
* AC Current (using both Voltage and Current CT).
* AC Voltage.
* DC Current.
* Dc Voltage.
* Thermocouple.
==DC Current==
==DC Current==
[[File:N22837947A_1.jpg | 240px| right]]
[[File:N22837947A_1.jpg | 240px| right]]
Line 28: Line 38:


==Thermocouple==
==Thermocouple==
===K Type===
K type thermocouple can be used and offer measuring range up to 1350 Celsius.

Revision as of 15:23, 15 November 2019

RPI_DCV8 is a 8 channels acquisition board for Raspberrypi. Any of AC current & voltage or DC current & voltage can be setup at assembly/purchase time.

  • 8 Channels.
  • Instrumentation amplifiers.
  • Measure RMS or Average signal.
  • Fit on Raspberrypi 4 holes mounting pattern.
  • Atmega328p Mcu (Arduino UNO)
  • MCP3208 ADC (12bits)
  • Screw Terminal connectors.


Channel Setup

The idea of the RPI_DCV8 brings a customisable base to setup each channel as per your requirement. We will setup for you the channel type and range at purchase time. Currently supported type of channels are:

  • AC Current (using both Voltage and Current CT).
  • AC Voltage.
  • DC Current.
  • Dc Voltage.
  • Thermocouple.

DC Current

DC current can be read using a Clamp meter suitable for DC. An example unit is the BT-605A where currents up to 600A can be measured.
The amplification stage can be adapted on the RPI_DCV8 to adjust for desired range.


AC Current

For measuring AC current current a Current Transformer (CT) must be used.

RPI_DCV8 can host the burden resistor for current output CT.

Thermocouple

K Type

K type thermocouple can be used and offer measuring range up to 1350 Celsius.