This page is for board specific information. More information can be found on the [[Raspberrypi_Current_and_Temperature_Sensor_Adaptor | generic page for RPICT series]].


* 4x AC Current Sensors
* 4x AC Current Sensors

Revision as of 15:09, 22 March 2017

Link to shop

This page is for board specific information. More information can be found on the generic page for RPICT series.

  • 4x AC Current Sensors
  • 4x DS18B20 Temperature Sensors
  • Attiny84 Mcu

Current Sensor

Recommended sensor: SCT-013-000

Burden Resistor: 24 Ohm

Connector: 3.5mm Jack

Default Voltage for power calculation: 240V (can be modified in firmware).

For AC current only.

Temperature Sensor

Connector: 3.5mm Jack

The intended temperature sensor is the DS18B20 which can be configure in either parasite or normal mode.

The connection to a 3.5mm jack connector is shown below.

NOTE: Raspberrypi must be switched off while connecting and disconnecting the temperature sensor.


Files

Sketch version 1.2